Open in the explorer

Set UNC interval to poll for changes on file servers

Type
User
GPO path
User Configuration › Policies › Administrative Templates › Microsoft OneNote 2016 › OneNote Options › Other
Supported on
At least Windows Server 2008 R2 or Windows 7
ADMX file
onent16.admx
Internal name
onent16/L_SetUNCIntervalToPollForChangesOnFileServers

Explanation

This policy setting allows you to change the synchronization interval at which OneNote will poll for changes on the server. When OneNote synchronizes a notebook on UNC, also known as SMB or Windows File shares, OneNote will receive notifications from the file server as well as poll the server looking for new updates on the server.

By making the interval faster it will make OneNote synchronize faster, but it also might cause performance issues on the server.

If you enable this policy setting, you may specify the number of seconds OneNote will poll.

If you disable or do not configure this policy setting, OneNote will automatically poll every 30 seconds.

Registry

HKEY_CURRENT_USER\software\policies\microsoft\office\16.0\onenote\options\save
Value name
not defined in the ADMX

Enable / disable values: not defined in the ADMX (see the options below).

PowerShell

PowerShell commands that write to the registry what the policy would write. Values in angle brackets (<…>) must be replaced.

Writing directly to the registry bypasses Group Policy: if a GPO manages this value, it will be rewritten at the next gpupdate; otherwise the value stays in place (the "tattooing" effect). Prefer a GPO or, locally, LGPO.exe. Run PowerShell as administrator for HKLM. Some policies need a restart or gpupdate /force.

Enable

# Enable: onent16/L_SetUNCIntervalToPollForChangesOnFileServers
$k = 'HKCU:\software\policies\microsoft\office\16.0\onenote\options\save'
if (-not (Test-Path -Path $k)) { New-Item -Path $k -Force | Out-Null }
# Interval to poll the server (seconds)
Set-ItemProperty -Path $k -Name 'folderpollinterval' -Value 30 -Type DWord  # between 1 and 3600

Disable

# Disable: onent16/L_SetUNCIntervalToPollForChangesOnFileServers
# No value is written in the "Disabled" state (nothing defined in the ADMX)

Revert to "Not configured"

# Revert to "Not configured": onent16/L_SetUNCIntervalToPollForChangesOnFileServers
$k = 'HKCU:\software\policies\microsoft\office\16.0\onenote\options\save'
Remove-ItemProperty -Path $k -Name 'folderpollinterval' -ErrorAction SilentlyContinue

Options (1)

LabelControlRegistry valueREG typeConstraints / details
Interval to poll the server (seconds)L_SetUNCIntervalToPollForChangesOnFileServersSpinIDNumeric boxdecimalfolderpollintervalREG_DWORD
Min: 1 · Max: 3600 · Default (UI): 30

Application

Microsoft 365 Apps / Office (Microsoft) — November 2026 templates

Official templates downloaded on November 12, 2026.