Reattach Interval
Explanation
When a VHD(x) volume is detached unexpectedly, the FSLogix system will attempt to reattach the volume. This value specifies the number of seconds to wait between retries. The default value is 10 seconds which is the same as "Not Configured".
Registry Entry: HKLM\SOFTWARE\Policies\FSLogix\ODFC\ReAttachIntervalSeconds
Type: DWORD
Values: Min = 1, Max = 60
Registry
HKEY_LOCAL_MACHINE\Software\Policies\FSLogix\ODFC- Value name
- not defined in the ADMX
Enable / disable values: not defined in the ADMX (see the options below).
PowerShell
PowerShell commands that write to the registry what the policy would write. Values in angle brackets (<…>) must be replaced.
Writing directly to the registry bypasses Group Policy: if a GPO manages this value, it will be rewritten at the next gpupdate; otherwise the value stays in place (the "tattooing" effect). Prefer a GPO or, locally, LGPO.exe. Run PowerShell as administrator for HKLM. Some policies need a restart or gpupdate /force.
Enable
# Enable: fslogix/OdfcReattachInterval
$k = 'HKLM:\Software\Policies\FSLogix\ODFC'
if (-not (Test-Path -Path $k)) { New-Item -Path $k -Force | Out-Null }
# Reattach Interval
Set-ItemProperty -Path $k -Name 'ReAttachIntervalSeconds' -Value 10 -Type DWord # between 1 and 60Disable
# Disable: fslogix/OdfcReattachInterval
# No value is written in the "Disabled" state (nothing defined in the ADMX)Revert to "Not configured"
# Revert to "Not configured": fslogix/OdfcReattachInterval
$k = 'HKLM:\Software\Policies\FSLogix\ODFC'
Remove-ItemProperty -Path $k -Name 'ReAttachIntervalSeconds' -ErrorAction SilentlyContinueOptions (1)
| Label | Control | Registry value | REG type | Constraints / details |
|---|---|---|---|---|
| Reattach IntervalOdfcReattachInterval | Numeric boxdecimal | ReAttachIntervalSeconds | REG_DWORD | Required · Min: 1 · Max: 60 · Default (UI): 10 |
Application
FSLogix (Microsoft) — October 2026 templates
October 2026 templates from pl4nty/web-admx-tool.